Home > Product > EPS

Ouyad EPS:

 
Apply range:
·Be fit for all kinds of three phase and single phase facility emergency power supply.
·Be fit for EPS lamps and lanterns centralize power supply.

Main function and characteristic:
·According to GB17945-2000 <<EPS lamps and lanterns>> product standard.
·Fire fighting linkage control function.
·Adopt singlechip real time detection single section battery capability.
·Adopt free-maintenance battery,can duty-cycle operation for more than 500 times high efficiency.
·Protection against output overload, short-circuit.
·Unique technic of singlechip control invert .
·Emergency transform time 0.01~5S adjustable(optional≤4ms)
·Can using PC to long distance control.
·Simpleness complete machine manage can keep watch and guard by self, autonomous switchover.
·LCD and LED optional


Load characteristic:
·Be fit for in mains(~220/380V)all kinds of three phase and single phase facility.
·Inductive load should consider power factor.
·To calculate electromotor load should include pickup current. 
 
 
EPS technical specification:

Model and rated capacity

(look at lectotype table)

Normal input、
output voltage

1/N~220V土 10%,50Hz土 5%

3/N~380V/220土10%,50Hz土5%

Emer-gency output

voltage

1/N~220V土 5%,50Hz土 1%

3/N~380V/220土5%,50Hz土1%

waveform

Sine wave,THD≤3%

Transfer time

0.01~5s(especial can reach≤4ms)

Power on time

90 minute(standard type)or collocate by user request

Power loop

Threeway (standard type)or collocate by user request

Apply load

All kinds of EPS illumnate、dynamical etc currency load

Overload capacity

120% normal working

Protections

Protection against short-circuit ,over-curren

Efficiency

>90%

Noise

<55dB

Battery

Maintenance free battery

Operational environment

temperature

—10℃~ +35℃

Relative humidity

≤90%

altitude

≤2000m

Dielectric strength

AC1500V/50Hz, one minute

Insulation resistance

≥ 50M?

Product standard

According to GB17945--2000<<EPS lamps and lanterns>> product standard

 

EPS specification table:

Model

Output power? (KW)

Overall dimension width*thickness*height

Weight (Kg)

Mounting means

YZD-A/0.5-J

0.5

550*240*800

65

Hanging or embed

YZD-A/1-J

1

750*260*1000

110

Hanging or embed

YZD-A/2-J

2

750*260*1400

180

Ground or hanging

YZD-A/3-J

3

750*260*1400

320

Ground or hanging

YZD-A/4-J

4

600*600*1600

390

Ground

YZD-A/5-J

5

800*600*1800

490

Ground

YZD-A/6-J

6

800*600*2000

580

Ground

YZD-A/7-J

7

800*600*2000

670

Ground

YZD-A/8-J

8

800*600*2200

720

Ground

YZD-A/9-J

9

800*600*2200

780

Ground

YZD-A/10-J

10

800*600*2200

860

Ground

YZD-A/12-J

12

800*600*2200

1020

Ground

YZD-A/15-J

15

800*600*2200

1430

Ground

YZD-A/20-J

20

(800*600*2200)*1battery tank

1960

Ground

YZD-A/25-J

25

(800*600*2200)*2battery tank

2520

Ground

YZD-A/30-J

30

(800*600*2200)*2battery tank

2540

Ground

YZD-A/50-J

50

(1000*800*2200)*2battery tank

3450

Ground

YZD-A/100-J

100

(1000*800*2200)*4battery tank

6010

Ground

YZD-A/160-J

160

(1000*800*2200)*7battery tank

12200

Ground

YZD-A/200-J

200

(1000*800*2200)*8battery tank

14660

Ground

Notice :this overall dimension for reference only,if change will not further notice. 200~~800KW dimension need customization,over 800KW use combine machine mode。

EPS for power equipment

Apply range:

Be fit for all kinds of three phase fire-fighting equipment(such as fire pump、fan etc)emergency power supply use.

Primary function and characteristic:

1.Has frequency conversion startup function.

2.Fire-fighting linkage control function.

3.Can directness drive fire-fighting electromotor load or control facility.

4.Adopt international advanced PWM technical and import module.

5.Emergency transfer time 0.01~5S adjustable

6.Can using PC to long distance control.

7.Simpleness complete machine manage can keep watch and guard by self, autonomous switchover.

8.Selectable control mode for spare equipment automatism switch etc

 

Load characteristic:

1.Be fit for all kinds of three-phase electrical appliance facility which power ~380V

2.Inductive not need to consider power factor.

3.Electromotor load adopt frequency conversion startup without regard to pickup current

PS for power equipment technical specification

Model and rated capacity

(look at lectotype table)

Normal input、
output voltage

3/N~380V/220V土 10%, 50Hz土 5%

Emerg-ency output

Voltage

3/N~380V/220V土 5%, 50Hz土 1%

waveform

SPWM

Transfer time

0.01~5s

Power on time

90 minute(standard type)or collocate by user request

Power loop

Two circuit (standard type)or collocate by user request

Apply load

All kinds of fire fighting three phase dynamical load

Overload capacity

120%,one minute

Protections

Protection against short-circuit,over-current、lack-phase

Efficiency

>90%

Noise

<65dB

Battery

Maintenance free battery

Operational environment

Temper-ature

—10℃~ +35℃

Relative humidity

≤90%

altitude

≤2000m

Dielectric strength

AC1500V/50Hz, one minute

Insulation resistance

≥ 50M?

 

EPS for power equipment specification table


Model

Output power? (KW)

Overall dimension width*thickness*height*pcs

Weight
(Kg)

Mounting means

YZD-B/1.5

1.5

750*260*1600

280

Hanging

YZD-B/2.2

2.2

750*260*1600

350

Ground

YZD-B/3.7

3.7

800*400*1800

480

Ground

YZD-B/5.5

5.5

800*400*1800

520

Ground

YZD-B/7.5

7.5

800*600*2200

620

Ground

YZD-B/11

11

800*600*2200

950

Ground

YZD-B/15

15

(750*600*2200)*2

1300

Ground

YZD-B/18.5

18.5

(750*600*2200)*2

1520

Ground

YZD-B/22

22

(800*600*2200)*2

1600

Ground

YZD-B/30

30

(800*600*2200)*2

2110

Ground

YZD-B/37

37

(600*600*2200)*3

2560

Ground

YZD-B/45

45

(600*600*2200)*3

3320

Ground

YZD-B/55

55

(800*600*2200)*3

3450

Ground

YZD-B/75

75

(800*600*2200)*3

4750

Ground

YZD-B/93

93

(1000*800*2200)*4

5840

Ground

YZD-B/110

110

(1000*800*2200)*4

12140

Ground

YZD-B/132

132

(1000*800*2200)*5

12450

Ground

YZD-B/160

160

(1000*800*2200)*6

13520

Ground

YZD-B/185

185

(1000*800*2200)*7

14200

Ground

YZD-B/200

200

(1000*800*2200)*7

15660

Ground

YZD-B/220

220

(1000*800*2200)*7

16900

Ground

Notice :this overall dimension for reference only,if change will not further notice. 220~~660KW dimension need customization,over 660KW use combine machine mode.

 
COPYRIGHT(C) 2007 BY OUYAD. ALL RIGHTS RESERVED.